"There is a time to be born, and a time to die; a time to break down, and a time to build up; a time to weep, and a time to laugh; a time to keep silence, and a time to speak" (Ecclesiastes 3, 2?7). There was a time when automata were designed like clocks. Androids will have the time of their creators, the state of the art in technology, a wealth of experience to draw from, as well as the capacity to carry out actions as being endowed with meaning. The machine will undergo a long period of nurturing, from which it will learn to shape some sort of identity.
Virtual Reality (VR) is increasingly being used in combination with psycho-physiological measures to improve assessment of distress in mental health research and therapy. However, the analysis and interpretation of multiple physiological measures is time consuming and requires specific skills, which are not available to most clinicians. To address this issue, we designed and developed a Decision Support System (DSS) for automatic classification of stress levels during exposure to VR environments. The DSS integrates different biosensor data (ECG, breathing rate, EEG) and behavioral data (body gestures correlated with stress), following a training process in which self-rated and clinical-rated stress levels are used as ground truth. Detected stress events for each VR session are reported to the therapist as an aggregated value (ranging from 0 to 1) and graphically displayed on a diagram accessible by the therapist through a web-based interface.
Collagen-gelatin-genipin-hydroxyapatite composite scaffolds colonized by human primary osteoblasts are suitable for bone tissue engineering applications: In vitro evidences
Background Monitoring joint angles through wearable systems enables human posture and gesture to be reconstructed as a support for physical rehabilitation both in clinics and at the patient's home. A new generation of wearable goniometers based on knitted piezoresistive fabric (KPF) technology is presented. Methods KPF single-and double-layer devices were designed and characterized under stretching and bending to work as strain sensors and goniometers. The theoretical working principle and the derived electromechanical model, previously proved for carbon elastomer sensors, were generalized to KPF. The devices were used to correlate angles and piezoresistive fabric behaviour, to highlight the differences in terms of performance between the single layer and the double layer sensors. A fast calibration procedure is also proposed. Results The proposed device was tested both in static and dynamic conditions in comparison with standard electrogoniometers and inertial measurement units respectively. KPF goniometer capabilities in angle detection were experimentally proved and a discussion of the device measurement errors of is provided. The paper concludes with an analysis of sensor accuracy and hysteresis reduction in particular configurations. Conclusions Double layer KPF goniometers showed a promising performance in terms of angle measurements both in quasi-static and dynamic working mode for velocities typical of human movement. A further approach consisting of a combination of multiple sensors to increase accuracy via sensor fusion technique has been presented.
This paper presents an innovative wearable kinesthetic glove realized with knitted piezoresistive fabric (KPF) sensor technology. The glove is conceived to capture hand movement and gesture by using KPF in a double layer configuration working as angular sensors (electro-goniometers). The sensing glove prototype is endowed by three KPF goniometers, used to track flexion and extension movement of metacarpo-phalangeal joint of thumb, index and middle fingers. The glove is devoted to the continuous monitoring of patients during their daily life activities, in particular for stroke survivors during their rehabilitation. The prototype performances have been evaluated in comparison with an optical tracking system considered as a gold standard both for relieving static and dynamic posture and gesture of the hand. The introduced prototype has shown very interesting figures of merit. The angular error, evaluated through the standard Bland Altman analysis, has been estimated in ? 3? which is slightly less accurate than commercial electro-goniometers. Moreover, a new conceptual prototype design, preliminary evaluated within this work, is presented and discussed in order to solve actual limitations in terms of number and type of sensor connections, avoiding mechanical constraints given by metallic inextensible wires and improving user comfort.
INTERNATIONAL JOURNAL OF HANDHELD COMPUTING RESEARCH
Volume
5
Pagination
13–29
Abstract
Stress is an increasingly recognized phenomenon that has negative effects on growing numbers of people. Stress assessment is a complex issue, but different studies have shown that monitoring user psychophysi- ological parameter during daily life can be greatly helpful in stress evaluation. In this context, the European Collaborative Project INTERSTRESS is aimed at designing and developing advanced simulation and sensing technologies for the assessment and treatment of psychological stress, based on mobile biosensors.In this study a wearable biosensor platform able to collect physiological and behavioral parameters is reported. The developed mobile platform, in terms of hardware and processing algorithms, is described. Moreover the use of this wearable biosensor platform in combination with advanced simulation technologies, such as virtual reality, offer interesting opportunities for innovative personal health-care solutions to stress.
Compared to standard laboratory protocols, the measurement of psychophysiological signals in real world experiments poses technical and methodological challenges due to external factors that cannot be directly controlled. To address this problem, we propose a hybrid approach based on an immersive and human accessible space called the eXperience Induction Machine (XIM), that incorporates the advantages of a laboratory within a life-like setting. The XIM integrates unobtrusive wearable sensors for the acquisition of psychophysiological signals suitable for ambulatory emotion research. In this paper, we present results from two different studies conducted to validate the XIM as a general-purpose sensing infrastructure for the study of human affective states under ecologically valid conditions. In the first investigation, we recorded and classified signals from subjects exposed to pictorial stimuli corresponding to a range of arousal levels, while they were free to walk and gesticulate. In the second study, we designed an experiment that follows the classical conditioning paradigm, a well-known procedure in the behavioral sciences, with the additional feature that participants were free to move in the physical space, as opposed to similar studies measuring physiological signals in constrained laboratory settings. Our results indicate that, by using our sensing infrastructure, it is indeed possible to infer human event-elicited affective states through measurements of psychophysiological signals under ecological conditions.
This paper presents a contribution to the problem of obtaining an optimal synthesis for shortest paths for a unicycle guided by an on–board limited Field Of–View (FOV) sensor, which must keep a given landmark in sight. Previous works on this subject have provided an optimal synthesis for the case in which the FOV is limited in the horizontal directions (H– FOV, i.e. left and right boundaries). In this paper we study the complementary case in which the FOV is limited only in the vertical direction (V–FOV, i.e. upper and lower boundaries). With respect to the H–FOV case, the vertical limitation is all but a simple extension. Indeed, not only the geometry of extremal arcs is different, but also a more complex structure of the synthesis is revealed by analysis. We will indeed show that there exist initial configurations for which the optimal path does not exist. In such cases, we provide an e–optimal path whose length approximates arbitrarily well any other shorter path. Finally, we provide a partition of the motion plane in regions such that the optimal or e–optimal path from each point in that region is univocally determined.
An Autologously Generated Platelet-Rich Plasma Suturable Membrane May Enhance Peripheral Nerve Regeneration after Neurorraphy in an Acute Injury Model of Sciatic Nerve Neurotmesis